SRAM Backup and Restore
For more information, view our SRAM Backup and Restore Video
Step 1
Turn machine off.
Step 2
Insert card in slot.
Step 3
Hold down and continue to hold right 2 soft keys under the DISPLAY (LCD/CRT).
Step 4
Power on the control.
Step 5
Continue to hold the soft keys until system monitor menu appears.
Step 6
Format card if it is not formatted by arrowing down to option 7 and hitting select.
Step 7
Arrow down to option number 5.
Step 8
Hit select.
Step 9
Arrow to option number 1 (CNC -> Memory card).
For twin turret, you must back up main and sub. You must also restore both main and sub.
Note to restore:
Step 1
Arrow to option number 2 (Memory Card -> CNC).
Step 2
Hit select.
Step 3
Arrow down to select END.
Step 4
Hit select.
Step 5
Power down and back up and you’re done. This backs up all parameters
Note:
- You can backup more than one machine on a single card only if the memory files size is different.
- If the memory file size is the same, it will overwrite the first file and not create a new one.
Get your Fanuc CNC machine back up and running.
TIE offers same day shipping on more than 100,000 Fanuc CNC parts in stock. We offer a 1 year in service warranty on all parts and repairs.
Shop PartsWas this helpful?